Deanta’s fire door range is third-party certified and tested to EN 1634-1. FD30 and FD60 options available in oak, glazed, white primed, black prefinished, walnut and flush styles.
FD30 & FD60 · Q-MARK· CERTIFIRE
Third-Party Certified Internal Fire Doors
WHY DEANTA
The Deanta Fire Door Difference
Deanta fire doors carry third-party certification from accredited bodies, with the fire door design tested to EN 1634-1 to meet building control specifications and Approved Document B. Consistent manufacturing then ensures every fire door we produce meets these certified standards.
Third-Party Fire Door Certification
All Deanta fire doors are independently tested and certified – no ifs, no shortcuts.
Full Manufacturing Control
We control every stage of fire door production, from glazing to finishing, for consistent quality.
Fire Doors Delivered to Your Deadline
We schedule around your project dates, so a fire door is never the thing holding up the job.
Fire Doors in Any Style
Modern, shaker and classic styles in a full range of finishes — fire doors you’d want on show.
THE CASE FOR CERTIFICATION
Why Choose Third-Party Certified?
Fire safety matters. Our third party certified fire doors offer protection that is becoming non-negotiable for specifiers and architects. Deanta’s range of FD30 and FD60 fire doors surpass the current UK fire door regulations. Unlike many UK manufacturers, Deanta fire doors offer full traceability.
Deanta has complete control over every stage of production. By controlling the manufacturing process, Deanta guarantees each fire door surpasses the required safety certifications.
Deanta’s fire doors are ideal for all residential properties, commercial buildings, and House in multiple occupancy (HMO). The range of fire doors match hundreds of panelling styles, colours, and finishes.

INSIDE THE PROCESS
Fire Door Testing
We have complete control over every stage of production. By controlling the manufacturing process, we guarantee each fire door surpasses the required safety certifications.
01 – DESIGN
Specification & Build
Every Deanta fire door starts from a defined design specification. Manufacture is logged and verified component by component.
02 – TESTING
Independent Laboratory Test
Manufacturing is witnessed by third-party certification body; doors are tested at a UKAS-accredited laboratory and the results are presented to Certifire and Q-Mark.
03 – AUDIT
Ongoing Audit Testing
To retain certification, doors are randomly pulled from the factory for further independent testing – verifying every batch is up to standard.
- Certifire
- Q-Mark
- UKAS
- EN 1634-1
FIRE RATINGS
Fire Door Options
Choose from third-party certified FD30 and FD60 fire doors.
FD30 - 30-Minute Fire Doors

Every Deanta fire door starts from a defined design specification. Manufacture is logged and verified component by component.
FD60 - 60-Minute Fire Doors

Manufacturing is witnessed by third-party certification body; doors are tested at a UKAS-accredited laboratory and the results are presented to Certifire and Q-Mark.
What to Ask When Buying a Fire Door?
Before you commit, make sure you ask the right questions:
- Is the fire door third party certified? – if not – it’s not good enough.
- Is the entire doorset compatible and compliant? – It’s not just the leaf that matters when it comes to fire door safety – hinges, frames, seals, and glass (when applicable) should be fully tested as a system.
- Can the manufacturer prove traceability for their fire doors? – You need documentation that shows test evidence and certification.
- Is the glazing fire-rated and installed by a certified team? – At Deanta, every fire door is – and it’s all done in-house.
- How quickly can the fire doors be delivered? – We offer 3-week lead times as standard on FD30 and FD60 fire doors – many other companies don’t.

THE DETAIL
What You Get With a Deanta Fire Door
- Certified to the relevant FD30 or FD60 standards.
- Third-party certification for full traceability and compliance.
- Doorsets supplied with fully compatible seals and frames.
- Premium core construction for long-lasting performance.
- Seamless integration with our full range of styles and finishes.
- Glass options manufactured in-house with Pilkington fire-rated glass.
- Expert support on hand for specifiers, contractors, and merchants.
TECHNICAL DETAILS
Fire Door Technical Information
We are proud to be one of the UK’s largest internal door manufacturers, we lead the way in producing premium internal fire doors, that not only exceed safety standards but raise the bar on quality and design.
About EN 1634-1
All our internal fire doors are tested to EN 1634-1, the European standard for fire resistance.
We’ve conducted over 100 EN 1634-1 fire tests across a wide range of designs and configurations, backed by comprehensive Field of Application (FOA) reports. These reports demonstrate the scope of our certification and offer detailed technical evidence, something many manufacturers can’t provide.
What makes our EN 1634-1 testing different?
- Covers single and double fire doors, including internal doors with glass, over panels, and side screens
- Doors are tested with full traceability
- Door heights up to 3m and widths up to 1.5m available
Our fire doors don’t just meet the minimum standard, they exceed it, futureproofing your projects for changing regulations, including, the phase-out of BS 476 by 2029.
Acoustic Performance
Fire safety and sound control often go hand-in-hand – especially in residential, hospitality, and commercial environments.
Some Deanta fire doors are tested to meet Part E of the UK Building Regulations, achieving sound reduction ratings above 29dB
Whether you’re specifying internal double doors, fire rated doors with glass, or solid core options. Deanta’s range includes acoustic solutions that help reduce sound transmission while maintaining fire safety.
Plus, many of our acoustic fire doors are also PAS 24 certified and Secured by Design approved – offering security and performance in one.
Installation
Correct installation of fire doors is essential. Even fire doors tested to the highest standard will fail if they are not fitted and installed correctly. Deanta recommend that all fire doors are installed by a trained and competent professional.
All Deanta fire doors are tested as a complete system, including frame, hardware, seals, and configuration. To maintain certification:
- Installation must follow parameters set out in the Field of Application (FOA)
- The door must be fitted using the correct frame type, fixings, and certified hardware
- Seals and components must be placed precisely as tested
We supply installation guides, outlining instructions to fit fire doors whilst following compliance.
Key Message: Always install Deanta fire doors using qualified professionals who understand fire door testing, certification, and legal compliance.
Door Hardware
Every component matters. That’s why Deanta tests its fire doors with a wide variety of hardware configurations – ensuring full compatibility and certification under EN 1634-1.
The Field of Application (FOA) provides guidelines on what hardware can be paired with our fire doors.
Unlike other manufacturers, we’ve tested locks and latches without intumescent protection, reducing installation time and cost – without compromising on safety. However we still recommend the use of intumescent pads for locks and hinges for FD30 and FD60 fire doors.
Hinges
We specify BS EN Grade 13 certified butt hinges for all of our FD30 rated doors.
Approved Deanta butt bearing hinge spec:
- Size: 90-110 x 30-35 (additional size available)
- Intumescent pads – details given on datasheets
- Placement and quantity: Minimum 3, 120-180 from head of leaf, 150-250 from base of leaf, and 3rd placed centrally – 4 hinges are required for doors over 2400
This approach ensures seamless installation while keeping to strict fire performance criteria.
KEY TERMS
Fire Door Glossary
Certifire Fire Doors
Certifire is a globally recognised third-party certification scheme for fire doors and other passive fire protection products. Working with Certifire, we ensure every Deanta fire door is independently tested, audited, and verified for consistent fire resistance and quality.
Q-Mark Fire Doors
Deanta fire doors are third party accredited by BM Trada’s Q-Mark scheme – a leading certification body in the UK. Using the Q-Mark certificate guarantees that Deanta manufactures its fire doors for consistency, traceability, and verified fire resistance. We are proud to be one of the few UK manufacturers committed to ongoing Q-Mark auditing and testing across our fire door range.
PAS24 Doorsets
Selected Deanta doorsets are tested to PAS24 standards, a high security benchmark for enhanced internal door protection. Being certified by PAS24 means our doorsets are tested to rigorous physical standards, involving physical attacks.
Secured by Design Doorsets
Our enhanced security doorsets are accredited by Secured by Design (SBD), an official police initiative focused on crime prevention through smart product design. SBD-approved doorsets meet the national standard for fighting crime.
Pilkington Glass for Doors
Deanta uses Pilkington as a glazing partner for its internal doors. Our trusted partner, Pilkington, is a globally recognised name for high-performance and high-quality glass. Pilkington offers strength and fire resistance options for our internal fire doors. Because we handle all glazing ourselves, you benefit from faster lead times and full quality control on every glass fire door.
Pyroguard Glass for Fire Doors
Deanta partners with Pyroguard, a leading manufacturer of glass for fire doors. Pyroguard’s advanced glazing offers integrity and insulation protection for up to 60 minutes (FD60). This ensures our glass fire doors meet the strictest European fire safety standards. Deanta ensures every fire door with glass delivers safety, clarity, and certified fire resistance.
FAQ
Fire Door FAQ
We hope we’ve covered most questions, but if you have any others then please don’t hesitate to contact us.
What is a fire door?
A fire door is a specially designed internal door that resists the spread of fire and smoke for a specific period (typically 30 or 60 minutes). It’s a life-saving safety feature required by law in many buildings.
How do I know if I need a fire door?
Fire doors are typically required in certain areas of homes (like between a garage and house) and in all multi-occupancy buildings or commercial properties. Your architect, builder, or building inspector can advise based on current regulations. Please refer to the Government website for further info – Fire Safety (England) Regulations 2022
Are Deanta fire doors certified?
Yes, all Deanta fire doors are third-party certified, which means they’ve been independently tested and verified to meet safety standards. We’re committed to full compliance and transparency.
Can I cut or trim a fire door?
Yes – but only within strict limits to maintain the fire certification.
- FD30 (FEATURE) fire doors can be trimmed by up to 30mm in total (maximum 15mm from any edge).
- FD60 (FEATURE) fire doors have much tighter tolerances and can only be trimmed by 1mm per edge.
- FD30 (FLUSH) fire doors can be trimmed by up to 6mm in total (maximum 3mm from any edge).
- FD60 (FLUSH) fire doors can be trimmed by up to 2mm in total (maximum 1mm from any edge).
Any trimming beyond these limits can invalidate the door’s certification and compromise safety. Always follow Deanta’s specific installation guidelines and speak to your supplier or installer before making any adjustments.
Do fire doors come with glass panels?
Yes, and at Deanta, all our glass fire doors use fire-rated glass. We handle all glazing in-house and use Pilkington fire glass, ensuring every component meets fire resistance standards.
Can I paint or varnish a fire door?
Yes, but only with approved finishes and as per our guidelines. Incorrect finishes can impact the fire performance. We offer prefinished options for peace of mind. If you have a specific question related to finishing your fire door, please reach out to our customer service team.
What hardware is needed for a fire door?
Hinges, closers are essential hardware and are required as they play a vital role in ensuring the fire door performs as required. Latches, locks, environmental seals, viewers and letterboxes are optional.
Do I need door frames as well?
Yes, a fire door is only effective when installed as part of a complete fire doorset which includes; frames, seals, and hardware. Deanta offers fully certified doorsets for this reason.
What is the difference between a fire door and a fire doorset?
A fire door is just the leaf; a doorset includes the door, frame, ironmongery, seals, and certification as a complete tested unit. Deanta fire doorsets are fully tested and compliant.
See the Full Testing